Get a GRIP on combustion with ONE hand.
The Wöhler A 400 Flue Gas Analyzers are the multi-functional instruments for residential and light commercial applications.
Available in two different setup!
Wohler A 400 Flue Gas Analyzer with flexible probe.
Wohler A 400 PRO Flue Gas Analyzer with traditional probe and hose assembly.
| O2: |
Range: 0 - 21 Vol.% Accuracy: ±3 Vol.% |
| CO: |
Sensor type: electrochemical Range: 0...4,000 ppm Resolution: 1 ppm Accuracy: ±5% f. m. , absolute ±20 ppm |
| Draft: |
Unit: inWC / psi / Pascal / mbar Range: ±40 inWC Resolution: 0.004 inWC Accuracy: ±2% f.m., absolute ±0.02 inWC |
| Flue Gas Temperature (TS) |
Unit: °F / °C Range: -4°F...1472°F Resolution: 0.2°F Accuracy: 32...257°F: ±4°F 257...482°F: ±6°F 482...752°F: ±8°F 252...1472°F: ±1.5% f.m |
| Air Temperature (TA): |
Unit: °F / °C Range: -4...248°F Resolution: 0.2°F Accuracy: ±2°F |
| Calculated Values: |
Eff./ SL: efficiency and losses according to ASME standards ETA / QS: efficiency and losses according to EN standards CO2 CO air free dew point excess air condensate quantity in condensing conditions |

To return a service case to Wohler USA, please use the RMA Request!
ATTENTION: The WUSA Service Deparment will be on vacation from May 11, 2010 date to May 19, 2010. No calibration or repair service will be available during this period.
RMA Request